Resolution of 176 Yb and 176 Lu interferences on 176 Hf to enable accurate 176 Hf/177 Hf isotope ratio analysis using ICP-QQQ with MS/MS
Aplikace | 2017 | Agilent TechnologiesInstrumentace
ICP/MS, ICP/MS/MS
ZaměřeníŽivotní prostředí
VýrobceAgilent Technologies
Klíčová slovaisotope, ammonia, isotopes, ratios, icp, reaction, overlaps, quad, resolution, ion, react, other, adduct, mineral, qqq, deviation, isobars, isotopic, pattern, mass, preserved, cell, elements, theoretical, processes, ions, existing, chemistry, suffer, msmass, overlap, single, isobaric, control, from, formed, commercial, dating, analyte, glenn, interference, woods, nebulizer, gas, product, tandem, new, micromist, capability, coexisting
Podobná PDF
Agilent ICP-MS Journal (November 2015 – Issue 63)
2016|Agilent Technologies|Ostatní
Agilent ICP-MS Journal November 2015 – Issue 63 Inside this Issue 2-3 176Hf/177Hf 4 Analysis of Undiluted Seawater using the Agilent 7900 ICP-MS with UHMI 5 China Hosts First Agilent-sponsored Petroleum R&D Conference 6 Collaboration Kicks Off with Opening…
Klíčová slova
icp, icplims, limsnpl, nplqqq, qqqpetroleum, petroleumseawater, seawaterisotope, isotopenuclear, nuclearagilent, agilentammonia, ammoniaoil, oilradionuclides, radionuclidessinopec, sinopecclicking, clickinguhmi
ICP-QQQ Applications in Geochemistry, Mineral Analysis, and Nuclear Science
2022|Agilent Technologies|Příručky
Applications of ICP-MS ICP-QQQ Applications in Geochemistry, Mineral Analysis, and Nuclear Science Application Compendium > Return to table of contents > Search entire document Explore New Opportunities in Geochemistry, Mineral Analysis, and Nuclear Science With the Agilent 8900 ICP-QQQ Agilent…
Klíčová slova
return, returncontents, contentstable, tableicp, icpree, reeqqq, qqqmass, masscps, cpscell, cellgas, gasybo, yboelement, elementshift, shiftrare, rarewwtp
Agilent ICP-MS Journal (August 2019. Issue 77)
2019|Agilent Technologies|Ostatní
Agilent ICP-MS Journal August 2019. Issue 77 Optimizing Conditions for High Quality Data with ICP-MS Page 1 Optimizing Conditions for High Quality Data with ICP-MS Pages 2-3 High-Resolution Elemental Bio-Imaging of Gd in Skin Tissue using LA-ICP-QQQ Pages 4-5 Tools…
Klíčová slova
icp, icpqqq, qqqcones, conesgbcas, gbcasagilent, agilentsupplier, supplierskin, skingadolinium, gadoliniumstandards, standardscontrast, contrastimaging, imagingtissue, tissueproduct, productagents, agentssetup
Handbook of ICP-QQQ Applications using the Agilent 8800 and 8900
2022|Agilent Technologies|Příručky
5th Edition Handbook of ICP-QQQ Applications using the Agilent 8800 and 8900 Primer > Return to table of contents > Search entire document Foreword Agilent Technologies launched its 8800 Triple Quadrupole ICP-MS (ICP-QQQ) at the 2012 Winter Conference on Plasma…
Klíčová slova
return, returncontents, contentsicp, icptable, tableqqq, qqqcps, cpsgas, gasmass, masscell, cellppt, pptdocument, documentconc, concentire, entiresearch, searchelements