Measuring Cadmium in Water

 

Podobná PDF

Toggle
Measuring Lead in Water
2019|Agilent Technologies|Aplikace
Application Brief Environmental Measuring Lead in Water Utilizing intelligent optimization of analysis parameters Element: Pb Matrix: Water Modifier: NH4H2PO4 + Mg(NO3)2 Instrumentation: Agilent 240Z Graphite Furnace AAS Standards: ISO 15586:2003 U.S. EPA Method 200.9 IS 10500; IS 14543, IS 13428…
Klíčová slova
ashing, ashinggraphite, graphitefurnace, furnaceatomize, atomizeash, ashfume, fumeplatform, platformoptimization, optimizationtube, tubelamp, lamplighted, lightedintelligent, intelligentctz, ctztemperatures, temperaturespyrolytic
Measuring Arsenic in Water
2019|Agilent Technologies|Aplikace
Application Brief Environmental Measuring Arsenic in Water Utilizing intelligent optimization of analysis parameters Element: As Introduction Matrix: Water Modifier: Pd(NO3)2 + Mg(NO3)2 Instrumentation: Agilent 240Z Graphite Furnace AAS From the World Health Organization (WHO) Arsenic is introduced into water through…
Klíčová slova
graphite, graphitefurnace, furnacearsenic, arsenicashing, ashingtube, tubelamp, lamplighted, lightedatomize, atomizepyrolytic, pyrolyticatomizing, atomizingplatform, platformwishes, wishesgfaas, gfaasoptimization, optimizationworry
Flame and Graphite Furnace Atomic Absorption Spectroscopy Application Compendium Table of Contents Solutions for Common AAS Problems 3 Determination of Cu, Fe, K, Mg, Mn, Na and Zn in Food Using AAS in Fast Sequential mode 6 Rapid Determination of…
Klíčová slova
abs, abselement, elementfurnace, furnacegraphite, graphitevalue, valuebackground, backgroundabsorption, absorptionpeak, peakash, ashlamp, lampatomic, atomicuptake, uptakegfaas, gfaasmeasured, measuredcertified
MEASURING LEAD IN WATER AS PER ISO:15586:2003
2018|Agilent Technologies|Aplikace
MEASURING LEAD IN WATER AS PER ISO:15586:2003 APPLICATION BRIEF Introduction Element: Lead Matrix: Water Regulation: ISO 15586:2003 Instrumentation: Agilent 240Z Graphite Furnace AAS The major sources of human exposure to lead (Pb) are food and drinking water. In 2008, the…
Klíčová slova
atomize, atomizelead, leadlamp, lampash, ashdrinking, drinkinggraphite, graphitemethodology, methodologyultraa, ultraaregia, regiazeeman, zeemangovernments, governmentslgc, lgcuses, usessurface, surfacelongitudinal