Direct measurement of trace rare earth elements (REEs) in high-purity REE oxide using the Agilent 8800 Triple Quadrupole ICP-MS with MS/MS mode
Aplikace | 2012 | Agilent TechnologiesInstrumentace
ICP/MS, ICP/MS/MS
ZaměřeníMateriálová analýza
VýrobceAgilent Technologies
Klíčová slovaree, rees, oxide, cell, trace, becs, analyte, measurement, elements, mass, react, mode, purity, gas, efficiently, matrix, bec, modes, element, octopole, measured, icp, ions, interferences, impurities, reaction, bias, gdo, applicable, high, chosen, operated, ion, analytes, deflect, can, glenn, removal, sugiyama, interference, naoki, product, due, abbreviated, woods, single, contaminants, commonly, different, other
Podobná PDF
Routine determination of trace rare earth elements in high purity Nd2 O3 using the Agilent 8800 ICP-QQQ
2015|Agilent Technologies|Aplikace
Routine determination of trace rare earth elements in high purity Nd2O3 using the Agilent 8800 ICP-QQQ Application note Geochemistry, mining and materials science Authors Juane Song1, Xiang-Cheng Zeng1, Dong Yan1 and Wei-ming Wu2 1 Agilent Technologies, China 2 Jiangxi University…
Klíčová slova
rees, reesree, reemass, massshift, shifthmi, hmiions, ionsreaction, reactionbecs, becsmode, modeenter, entertrace, tracecell, cellrare, rareoctopole, octopoleelement
ICP-QQQ Applications in Geochemistry, Mineral Analysis, and Nuclear Science
2022|Agilent Technologies|Příručky
Applications of ICP-MS ICP-QQQ Applications in Geochemistry, Mineral Analysis, and Nuclear Science Application Compendium > Return to table of contents > Search entire document Explore New Opportunities in Geochemistry, Mineral Analysis, and Nuclear Science With the Agilent 8900 ICP-QQQ Agilent…
Klíčová slova
return, returncontents, contentstable, tableicp, icpree, reeqqq, qqqmass, masscps, cpscell, cellgas, gaselement, elementshift, shiftybo, yborare, rarerees
Agilent ICP-MS Journal (November 2014 – Issue 59)
2014|Agilent Technologies|Ostatní
Agilent ICP-MS Journal November 2014 – Issue 59 Inside this Issue 2-3 Maximizing Throughput of Soil Sample Analysis using 7900 ICP-MS with ISIS 3 Discrete Sampling 4-5 Direct Analysis of Trace Rare Earth Elements in High Purity Nd2O3 using 8800…
Klíčová slova
icp, icpsoftware, softwarerees, reesmasshunter, masshuntersma, smaagilent, agilentree, reematrix, matrixhigh, highscience, sciencemaintenance, maintenanceaccess, accessplasma, plasmasoil, soilelements
Characterization of Rare Earth Elements used for Radiolabeling Applications by ICP-QQQ
2020|Agilent Technologies|Aplikace
Application Note Materials, Nuclear, Pharmaceutical Characterization of Rare Earth Elements used for Radiolabeling Applications by ICP-QQQ Analysis of radiogenic REE isotopes in bulk REE matrices Introduction Authors B. Russell , P. Ivanov B. Webster1,2, D. Read1,2 1 1 Nuclear Metrology…
Klíčová slova
ree, reelanthanide, lanthanidelanthanides, lanthanidesradio, radiotrace, traceelement, elementicp, icpqqq, qqqimpurities, impuritiesstarting, startingchemical, chemicalradioactive, radioactiveisotopes, isotopesmeasured, measuredseparation