Biodiesel in diesel fuel using the Agilent 5500t FTIR by EN14078 method
Aplikace | 2011 | Agilent TechnologiesInstrumentace
FTIR Spektroskopie
ZaměřeníPrůmysl a chemie
VýrobceAgilent Technologies
Klíčová slovamicrolab, biodiesel, diesel, fuel, tumbler, software, seelenbinder, john, measured, ftir, objective, predicted, petroleum, transmission, each, esters, absorbance, presents, calculate, percent, configured, actual, fatty, lowest, screen, quantify, error, experiment, author, generate, above, measurements, methyl, used, example, per, method, average, results, easily, cell, amount, from, concentrations, using, shown, spectrometer, determination, acid, products
Podobná PDF
Low level detection of biodiesel in diesel fuel using the Agilent 5500t FTIR spectrometer
2011|Agilent Technologies|Aplikace
Low level detection of biodiesel in diesel fuel using the Agilent 5500t FTIR spectrometer Application Note Author Frank Higgins Agilent Technologies, Connecticut, USA Background Recent increases in production of biodiesel along with the high cost of crude oil have encouraged…
Klíčová slova
biodiesel, biodieseldiesel, dieselengines, enginesmicrolab, microlabftir, ftirregular, regularincumbent, incumbentdetermine, determinehiggins, higginsincreases, increasesencouraged, encouragedlinearly, linearlyinstability, instabilityfrank, frankproducers
Test method for low level detection of biodiesel in diesel using the Agilent 5500t FTIR spectrometer
2011|Agilent Technologies|Aplikace
Test method for low level detection of biodiesel in diesel using the Agilent 5500t FTIR spectrometer Application Note Author John Seelenbinder and Frank Higgins Agilent Technologies, Connecticut, USA Introduction Agilent Technologies 4500t and 5500t FTIR spectrometers are gaining rapid acceptance…
Klíčová slova
biodiesel, biodieseldiesel, dieselfuel, fueltransmission, transmissionmethod, methodinterface, interfacesecv, secvvalidation, validationcalibration, calibrationcross, crossatr, atrerror, erroraccurately, accuratelyspecifies, specifiescarbonyl
Portable measurement of biodiesel in diesel fuels by ASTM D7371-07 (FTIR- ATR-PLS method) with the Agilent 5500t FTIR spectrometer
2011|Agilent Technologies|Aplikace
Portable measurement of biodiesel in diesel fuels by ASTM D7371-07 (FTIRATR-PLS method) with the Agilent 5500t FTIR spectrometer Application Note Author Frank Higgins Agilent Technologies Connecticut, USA Background Biodiesel blending with current ultra low sulfur diesel (ULSD) fuels is increasing…
Klíčová slova
biodiesel, biodieseldiesel, dieselcetane, cetanefuels, fuelsfuel, fuelmicrolab, microlabdiamond, diamondvol, volatr, atrqualification, qualificationulsd, ulsdindex, indexfleet, fleeterror, errorseasonal
Fuel Analysis with the Agilent 4500 Series FTIR: Monitoring Refinery Formulation to Ensure the Production of FAME-Free Marine Diesel Fuel
2013|Agilent Technologies|Aplikace
Fuel Analysis with the Agilent 4500 Series FTIR: Monitoring Refinery Formulation to Ensure the Production of FAME-Free Marine Diesel Fuel Application Note Authors Introduction Pik Leung Tang Biodiesel (FAME) is increasingly used in diesel fuel formulations, however, even small amounts…
Klíčová slova
diesel, dieselbiodiesel, biodieselfuel, fuelmarine, marinedialpath, dialpathbatch, batchfame, fametest, testrefinery, refinerymeasuring, measuringreformate, reformatemeasurement, measurementviscous, viscousbatches, batchesrefiner