ICPMS
Další informace
WebinářeO násKontaktujte násPodmínky užití
LabRulez s.r.o. Všechna práva vyhrazena. Obsah dostupný pod licencí CC BY-SA 4.0 Uveďte původ-Zachovejte licenci.
Pořadatel
Mettler-Toledo
Mettler-Toledo
METTLER TOLEDO je globální výrobce a prodejce přesných přístrojů pro použití v laboratorních, průmyslových a potravinářských maloobchodních aplikacích.
Tagy
Termální analýza
LinkedIn Logo

Determining Oxidation Induction Time by DSC

ZÁZNAM | Proběhlo Čt, 30.5.2024
Jak se diferenciální skenovací kalorimetrie používá ke zkoumání doby indukce oxidace olejů, polymerů a potravin?
Přejít na webinář
METTLER TOLEDO: Determining Oxidation Induction Time by DSC
METTLER TOLEDO: Determining Oxidation Induction Time by DSC

Oxidation is a chemical reaction in which a substance loses electrons, either by the addition of oxygen or by the removal of hydrogen. The oxidation of materials can lead to failure in their particular use or application. For example, polymers become brittle, edible oils become rancid, mineral oils undergo polymerization, and petrochemical products exhibit a change in viscosity.

  • Introduction to oxidation induction time (OIT) and thermal analysis
  • Principles of OIT and oxidation onset temperature (OOT)
  • Comparison of OIT and OOT
  • Different DSC techniques for studying OIT and OOT
  • Industries where OIT and OOT investigations are used
  • Application examples

OIT Measurements

The OIT test is a standardized isothermal measurement performed with a differential scanning calorimeter (DSC) to measure the resistance of a material to oxidation. The sample is heated in the presence of air or oxygen and the time it takes for the material to oxidize is measured. The test is typically used to evaluate the oxidative stability of oils, polymers, and foods, as well as to assess the effectiveness of antioxidants in preventing oxidation. These tests are frequently employed for process development and quality control.

Join the webinar to explore the potential applications of the OIT technique, and get the chance to ask our experts your questions!

Presenter: Angela Hammer, Dr. sc. nat. ETH**

Dr. Angela Hammer received a Ph.D. in Analytical Chemistry (development of immobilized components for the use in ion-selective electrodes based on polyurethane membranes) from the Institute of Organic Chemistry at the Swiss Federal Institute of Technology in Zürich, Switzerland. She then joined Sika Technology AG in Zurich, Switzerland, as an analytical chemist. In 2007, she joined METTLER TOLEDO and has worked there since as an application specialist for Thermal Analysis. In her present position, she uses, teaches, and supports DSC, TGA, TMA, and DMA instruments for the METTLER TOLEDO’s Materials Characterization Group located at the head office in Switzerland.

Mettler-Toledo
LinkedIn Logo
 

Mohlo by Vás zajímat

Analysis of rare earth elements in clay using XRF and XRD

Aplikace
| 2026 | Thermo Fisher Scientific
Instrumentace
XRD
Výrobce
Thermo Fisher Scientific
Zaměření
Materiálová analýza

Measurement of TOC in Chloroisocyanuric Acid Used as Disinfectant

Aplikace
| 2026 | Shimadzu
Instrumentace
TOC
Výrobce
Shimadzu
Zaměření
Farmaceutická analýza

High Precision Analysis of Major Components in Precious Metals by ICP-OES

Aplikace
| 2025 | Agilent Technologies
Instrumentace
ICP-OES
Výrobce
Agilent Technologies
Zaměření
Materiálová analýza

Analysis of Heavy Metals in Baby FoodUsing ICP-MS

Aplikace
| 2025 | Shimadzu
Instrumentace
ICP/MS
Výrobce
Shimadzu
Zaměření
Potraviny a zemědělství

ICP-OES Analysis of Copper Recovered from Li-Ion Batteries for Foil Manufacturing

Aplikace
| 2025 | Agilent Technologies
Instrumentace
ICP-OES
Výrobce
Agilent Technologies
Zaměření
Materiálová analýza
Další projekty
GCMS
LCMS
Sledujte nás
Další informace
WebinářeO násKontaktujte násPodmínky užití
LabRulez s.r.o. Všechna práva vyhrazena. Obsah dostupný pod licencí CC BY-SA 4.0 Uveďte původ-Zachovejte licenci.